Search results
99 Found
Mersen
Fuse, Square Body, Micro-Switch, Remote Signaling, 2200V AC/DC
Item #: 680506
CAT #: MCR3E1-5N
UPC: 605340357830
Company wide:
Discontinued
Mersen
100-200A J FUSE REDUCER PR
Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications. 600 Volts 100 to 200 Amps Class J series.
Item #: 188729
CAT #: J216
UPC: 782001753474
Category:
Fuse Reducers
Company wide:
Mersen
Fuse, Square Body, Micro-Switch, Remote Signaling, 2200V AC/DC
Fuse, Square Body, Micro-Switch, Remote Signaling, Insulated Up to 2200 Volt AC/DC, 1 Normally Open/Normally Closed Contacts
Item #: 680506
CAT #: MCR3E1-5N
UPC: 605340357830
Category:
Miscellaneous Fuse Accessories
Company wide:
Discontinued
Mersen
18419 IEC CYLINDRICAL
18419 IEC CYLINDRICAL FUSE LINKS
Item #: 1057188
CAT #: R214628
UPC: 430399009443
Category:
Fuse Links
Company wide:
Mersen
SAFETY COVER 250V 30A H/K/R
Mersen DFC dead-front fuse covers snap on to individual fuses installed in fuse blocks, covering exposed live clips and terminals and reducing accidental contact by personnel. They are sized to fit class G, H, J, K, R, CC or midget fuses for increased safety and optional open-fuse indication. All DFC dead-front covers are reusable when a fuse is replaced - simply detach from the open fuse and re-attach to the new replacement fuse. On indicator models an orange indicator light will illuminate to indicate an open fuse 250 Volts 30 amps Class H-K-R series.
Item #: 14976
CAT #: DFC-9
UPC: 782001753726
Category:
Fuse Covers
Company wide:
Mersen
ADD-ON SWITCH QUICK CONNECT
Add-On-Switches contain one single-pole doublethrow contact rated 4 amperes resistive and 1 ampere inductive at 250V AC maximum. Two versions of the Add-On-Switch are available. Catalog number -Q accommodates quick connects
Item #: 137785
CAT #: AOS-Q
UPC: 782001940751
Category:
Miscellaneous Fuse Accessories
Company wide:
Mersen
NH 000 32A 690V GG
The NH system is classified among plug-in fuse systems and is composed of: ò fuse-base (possibly including terminal covers and phase barriers) ò fuse-link with blade contact ò fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type gG NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents. 690 Volts 32 Amps gG NH000 series.
Item #: 769881
CAT #: N228448
UPC: 086500087727
Category:
Fuse Links
Company wide:
Mersen
100-400A J FUSE REDUCER PR
Mersen fuse reducers allow the use of lower rated fuses in existing equipment having clips with higher ampere ratings. The use of closer rated time-delay fuses can improve circuit protection. For example, renewable or one-time fuses feeding a motor can be replaced with fuses sized closer to the motor nameplate current. Non-rejection reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit Class J clips. Class J fuse reducers are not for bolt on applications. 600 Volts 100 to 400 Amps Class J series.
Item #: 228360
CAT #: J416
UPC: 782001753481
Category:
Fuse Reducers
Company wide:
Mersen
SAFETY COVER 600V 100A HKR IND
Mersen DFC dead-front fuse covers snap on to individual fuses installed in fuse blocks, covering exposed live clips and terminals and reducing accidental contact by personnel. They are sized to fit class G, H, J, K, R, CC or midget fuses for increased safety and optional open-fuse indication. All DFC dead-front covers are reusable when a fuse is replaced - simply detach from the open fuse and re-attach to the new replacement fuse. On indicator models an orange indicator light will illuminate to indicate an open fuse 600 Volts 100 amps Class H-K-R w/indicator series.
Item #: 486027
CAT #: DFC-8I
UPC: 782001753801
Category:
Fuse Covers
Company wide:
99 Items found