"frqmc-x"

7 Found
ABB

Mini Circuit Breaker 1p C 0.5a 480y/27

Item #: 1072748
CAT #: S201-C0.5
UPC:
Sign In or Register to view pricing and more.
ABB

Abb S202p-z20 Mcb 2p Z 20a 480y/277

Item #: 37866
CAT #: S202P-Z20
UPC:
Sign In or Register to view pricing and more.
ABB

Mcb 3p K 0.2a 240bcpd

Item #: 1661673
CAT #: S203U-K0.2
UPC:
Sign In or Register to view pricing and more.
ABB

vMini Circuit Breaker 2 Pole D 50 Amp 480y/277

Item #: 1033947
CAT #: S202-D50
UPC:
Sign In or Register to view pricing and more.
ABB

Abb S201up-k16 Mcb 1p K 16a 480y/27

Item #: 492541
CAT #: S201UP-K16
UPC:
Sign In or Register to view pricing and more.
ABB

Abb S201p-k4 Mcb 1p K 4a 480y/277 S

Item #: 1278856
CAT #: S201P-K4
UPC:
Sign In or Register to view pricing and more.
ABB

Busbar 2.0 Meters

Item #: 496458
CAT #: ZLS200
UPC:
Sign In or Register to view pricing and more.
ABB

Mini Circuit Breaker 1p C 0.5a 480y/27

ABB; Miniature Circuit Breaker; System Pro M Compact; S200; Voltage Rating: 230/400, 480y/277 Vac; Amperage Rating: 0.5 Amp; Frequency Rating: 50/60 Hz; Trip Type: Thermal Magnetic; Trip Range: Magnetic: 2.5 - 5 Amp, Thermal: 0.625 Amp; Interrupt Rating: 6 Kamp, 10 Kamp Ultimate; Number Of Poles: 1; Enclosure: Ip20, Ip40 With Cover; Actuator: Insulation Group Ii, Black, Sealable, I/o Marking; Material: Insulation Group I, Ral 7035; Length: 69 Mm; Width: 17.5 Mm; Height: 88 Mm; Operating Temperature: -25 To +55 Deg C; Environmental Conditions: Storage Temperature: -40 To 70 Deg C; Mounting: Din Rail: Th35-15 (35 Mm Length X 15 Mm Width), Th35-7.5 (35 Mm Length X 7.5 Mm Width); Recommended Screw Driver: Pozidriv2; Internal Resistance: 5500 Milohm Per Pole; Power Loss: 1.4 Wtt Per Pole; Connecting Capacity: Conductor: 18 - 4 Awg, Busbar: 18 - 8 Awg; Tightening Torque: 25 In-lb; Insulation Voltage: Phase To Ground: 250 Vac, Phase To Phase: 500 Vac;tripping Characteristic: C; Energy Limiting Class: 3; Endurance: Electrical Andmechanical: 20000 Cycles; Dielectric Test Voltage: 2 Kv At 50/60 Hz For 1 Mint;impulse Withstand Voltage: 4 Kv; Overvoltage Category: Iii; Contact Position Indication: On/off; Pollution Degree: 2
Item #: 1072748
CAT #: S201-C0.5
UPC:
Sign In or Register to view pricing and more.
ABB

Abb S202p-z20 Mcb 2p Z 20a 480y/277

Abb; Miniature Circuit Breaker; System Pro M Compact; S200p; Voltage Rating: 400, 480y/277 Vac; Amperage Rating: 20 Amp; Frequency Rating: 50/60 Hz; Trip Type:thermal Magnetic; Trip Range: Magnetic: 40 - 60 Amp, Thermal: 21 Amp; Interruptrating: 25 Kamp; Number Of Poles: 2; Enclosure: Ip20, Ip40 With Cover; Actuator:insulation Group Ii, Black, Sealable, I/o Marking; Material: Insulation Group I,ral 7035; Length: 69 Mm; Width: 35 Mm; Height: 88 Mm; Operating Temperature: -25to +55 Deg C; Environmental Conditions: Storage Temperature: -40 To 70 Deg C; Endurance: Electrical And Mechanical: 20000 Cycles; Tightening Torque: 25 In-lb; Connecting Capacity: Conductor: 18 - 4 Awg, Busbar: 18 - 8 Awg; Mounting: Din Rail: Th35-15 (35 Mm Length X 15 Mm Width), Th35-7.5 (35 Mm Length X 7.5 Mm Width);recommended Screw Driver: Pozidriv 2; Insulation Voltage: Phase To Ground: 250 Vac, Phase To Phase: 500 Vac; Energy Limiting Class: 3; Contact Position Indication: On/off; Pollution Degree: 2; Overvoltage Category: Iii; Dielectric Test Voltage: 2 Kv At 50/60 Hz For 1 Mint; Impulse Withstand Voltage: 4 Kv
Item #: 37866
CAT #: S202P-Z20
UPC:
Sign In or Register to view pricing and more.
ABB

Mcb 3p K 0.2a 240bcpd

Abb; Miniature Circuit Breaker; System Pro M Compact; S200u; Voltage Rating: 400- 440 Vac; Amperage Rating: 0.2 Amp; Frequency Rating: 50/60 Hz; Trip Type: Thermal Magnetic; Trip Range: Magnetic: 1.6 - 2.4 Amp, Thermal: 0.21 Amp; Interruptrating: 10 Kamp; Number Of Poles: 3; Enclosure: Ip20, Ip40 With Cover; Actuator:insulation Group Ii, Black, Sealable, I/o Marking; Material: Insulation Group I,ral 7035; Length: 71 Mm; Width: 52.5 Mm; Height: 92 Mm; Environmental Conditions: Storage Temperature: -40 To 70 Deg C; Tightening Torque: 25 In-lb; Mounting: Din Rail: Th35-15 (35 Mm Length X 15 Mm Width), Th35-7.5 (35 Mm Length X 7.5 Mm Width); Connecting Capacity: Conductor: 18 - 4 Awg, Busbar: 18 - 8 Awg; Recommended Screw Driver: Pozidriv 2; Tripping Characteristic: K; Energy Limiting Class:3; Insulation Voltage: Phase To Ground: 250 Vac, Phase To Phase: 500 Vac; Impulse Withstand Voltage: 4 Kv; Dielectric Test Voltage: 2 Kv At 50/60 Hz For 1 Mint;contact Position Indication: On/off; Overvoltage Category: Iii; Endurance: Electrical And Mechanical: 20000 Cycles; Pollution Degree: 2
Item #: 1661673
CAT #: S203U-K0.2
UPC:
Sign In or Register to view pricing and more.
ABB

vMini Circuit Breaker 2 Pole D 50 Amp 480y/277

ABB; Miniature Circuit Breaker; System Pro M Compact; S200; Voltage Rating: 400,480y/277 Vac; Amperage Rating: 50 Amp; Frequency Rating: 50/60 Hz; Trip Type: Thermal Magnetic; Trip Range: Magnetic: 500 - 1000 Amp, Thermal: 62.5 Amp; Interrupt Rating: 6 Kamp, 10 Kamp Ultimate; Number Of Poles: 2; Enclosure: Ip20, Ip40 With Cover; Actuator: Insulation Group Ii, Black, Sealable, I/o Marking; Material: Insulation Group I, Ral 7035; Length: 69 Mm; Width: 35 Mm; Height: 88 Mm; Operating Temperature: -25 To +55 Deg C; Environmental Conditions: Storage Temperature: -40 To 70 Deg C; Mounting: Din Rail: Th35-15 (35 Mm Length X 15 Mm Width), Th35-7.5 (35 Mm Length X 7.5 Mm Width); Internal Resistance: 1.3 Milohm Per Pole;power Loss: 3.25 Wtt Per Pole; Tightening Torque: 25 In-lb; Connecting Capacity:conductor: 18 - 4 Awg, Busbar: 18 - 8 Awg; Recommended Screw Driver: Pozidriv 2;energy Limiting Class: 3; Insulation Voltage: Phase To Ground: 250 Vac, Phase Tophase: 500 Vac; Tripping Characteristic: D; Pollution Degree: 2; Endurance: Electrical: 10000 Cycles, Mechanical: 20000 Cycles; Contact Position Indication: On/off; Overvoltage Category: Iii; Dielectric Test Voltage: 2 Kv At 50/60 Hz For 1mint; Impulse Withstand Voltage: 4 Kv
Item #: 1033947
CAT #: S202-D50
UPC:
Sign In or Register to view pricing and more.
ABB

Abb S201up-k16 Mcb 1p K 16a 480y/27

Abb S201up-k16 Mcb 1p K 16a 480y/27Abb; Miniature Circuit Breaker; System Pro M Compact; S200up; Voltage Rating: 230 - 277 Vac; Amperage Rating: 16 Amp; Frequency Rating: 50/60 Hz; Trip Type: Thermal Magnetic; Trip Range: Magnetic: 128 - 192 Amp, Thermal: 16.8 Amp; Interruptrating: 10 Kamp; Number Of Poles: 1; Enclosure: Ip20, Ip40 With Cover; Actuator:insulation Group Ii, Black, Sealable, I/o Marking; Material: Insulation Group I,ral 7035; Length: 71 Mm; Width: 17.5 Mm; Height: 100 Mm; Operating Temperature:-25 To +55 Deg C; Environmental Conditions: Storage Temperature: -40 To 70 Deg C; Recommended Screw Driver: Pozidriv 2; Mounting: Din Rail: Th35-15 (35 Mm Length X 15 Mm Width), Th35-7.5 (35 Mm Length X 7.5 Mm Width); Connecting Capacity: Conductor: 18 - 4 Awg, Busbar: 18 - 8 Awg; Tightening Torque: 25 In-lb; Energy Limiting Class: 3; Insulation Voltage: Phase To Ground: 250 Vac, Phase To Phase: 500 Vac; Tripping Characteristic: K; Contact Position Indication: On/off; Endurance: Electrical And Mechanical: 20000 Cycles; Impulse Withstand Voltage: 4 Kv; Overvoltage Category: Iii; Dielectric Test Voltage: 2 Kv At 50/60 Hz For 1 Mint; Pollution Degree: 2
Item #: 492541
CAT #: S201UP-K16
UPC:
Sign In or Register to view pricing and more.
ABB

Abb S201p-k4 Mcb 1p K 4a 480y/277 S

Abb; Miniature Circuit Breaker; System Pro M Compact; S200p; Voltage Rating: 230/400, 480y/277 Vac; Amperage Rating: 4 Amp; Frequency Rating: 50/60 Hz; Trip Type: Thermal Magnetic; Trip Range: Magnetic: 32 - 48 Amp, Thermal: 4.2 Amp; Interrupt Rating: 25 Kamp; Number Of Poles: 1; Enclosure: Ip20, Ip40 With Cover; Actuator: Insulation Group Ii, Black, Sealable, I/o Marking; Material: Insulation Group I, Ral 7035; Length: 69 Mm; Width: 17.5 Mm; Height: 88 Mm; Operating Temperature: -25 To +55 Deg C; Environmental Conditions: Storage Temperature: -40 To 70deg C; Connecting Capacity: Conductor: 18 - 4 Awg, Busbar: 18 - 8 Awg; Tightening Torque: 25 In-lb; Recommended Screw Driver: Pozidriv 2; Mounting: Din Rail: Th35-15 (35 Mm Length X 15 Mm Width), Th35-7.5 (35 Mm Length X 7.5 Mm Width); Energy Limiting Class: 3; Insulation Voltage: Phase To Ground: 250 Vac, Phase To Phase: 500 Vac; Tripping Characteristic: K; Dielectric Test Voltage: 2 Kv At 50/60hz For 1 Mint; Overvoltage Category: Iii; Pollution Degree: 2; Impulse Withstandvoltage: 4 Kv; Endurance: Electrical And Mechanical: 20000 Cycles; Contact Position Indication: On/off
Item #: 1278856
CAT #: S201P-K4
UPC:
Sign In or Register to view pricing and more.
ABB

Busbar 2.0 Meters

ABB 110 Pole, 100 Amp Busbar For L1, L2, L3, N And Pe, 10mm X 3mm
Item #: 496458
CAT #: ZLS200
UPC:
Sign In or Register to view pricing and more.
Page 1 of 1
7 Items found